OneCommand™ Manager Application P007997-01A Rev. B
13. Diagnostics
LightPulse FC HBA Diagnostics
200
To run advanced diagnostics tests, click Advanced Diagnostic Tests on the Diagnostics
tab to view the Diagnostic Test Setup dialog box.
You can run four types of tests:
PCI Loopback
Internal Loopback
External Loopback
End-to-End (ECHO)
Note: You cannot run the External Loopback test and ECHO test concurrently. If you
select External Loopback the ECHO test section is disabled and vice versa.
Test results and the status of running tests are time stamped and appear in the Test Log
area.
Figure 13-6 Diagnostic Test Setup
Running Loopback Tests
To run a loopback test, use the Loopback Test section of the Advanced Diagnostics
dialog box.